Table of Contents |
---|
...
Code Block | ||
---|---|---|
| ||
sapmsECC 3600/tcp |
(NN = your Instance Number /System Number)
Old:
Note |
---|
Be advised, the Performer Suite (PS) needs to be restarted to load in any system changes you did. Example: You adjusted your services file or pasted new LIB RFC files into your System32 folder -> Restart your PS. If you don't restart the PS, it could happen to fail to connect successfully, even if your system parameter is now correct. |
...
3- Error (Connect to SAP gateway failed)
Performer Suite log file writes an error:
Code Block | ||
---|---|---|
| ||
T:3524 Error in program 'BI Docu Performer': ======> SAP_CMINIT3 : rc=20 > Connect to SAP gateway failed ... LOCATION CPIC (TCP/IP) on local host ERROR internal error ... RELEASE 720 COMPONENT NI (network interface) VERSION 40 RC -1 MODULE nixxi.cpp LINE 825 DETAIL NiIInitSocket SYSTEM CALL WSASocket, socket ERRNO 10022 ERRNO TEXT WSAEINVAL: Invalid argument COUNTER 2 |
...
- SAP-Router used: 3299 + 3399
- No SAP-Router used: 32<NN> + 33<NN>
(NN = your Instance Number /System Number)
...
BO ports
- 6400 (Central Management Server)
- 6405 (Connection server Business Objects)
...
HANA ports
- 80<instance number>
- 43<instance number>
(NN = your Instance Number /System Number)
...