You are currently setting up your initial BO connection, but the connection fails when you press "Connect" in the Performer Suite.
Our BO setup guide, which we recommend, is only as good as your CMC is maintained by your BO administrator.
This means, that there are possibilities that your connection to your BO fails, even if your configuration in the Performer Suite matches the settings from your CMC.
...
The information in your CMC are only free text fields that must be correctly maintained by your BO administrator.
Quick-Win Solution
Note |
---|
This solution assumes that the RESTful Web Service is also running on the web application server where your BOE application is running. (which is the case with a default installation > 4.2 SP5). |
To get a working URL, just take the URL used in your browser to open your BI Launchpad or CMC.
Then take only protocol, server, and port (if specified).
Truncate everything after that.
This results in e.g. https://10.118.169.25:8080/
Then use this and append add the paths accordingly:
- /biprws
- /BOE/OpenDocument/opendoc/openDocument.jsp
- /dswsbobje
Note |
---|
This procedure assumes that the RESTful Web Service is also running on the web application server where your BOE application is running. (which is the case with a default installation > 4.2 SP5). |
...
If you need further assistance, please to create a ticket in our Help Desk.
Please do not forget to attach the PerformerSuite.log file for easier troubleshooting.